Micro Current Sensor

Material: Plastic
Certification: CE
Customized: Customized
Trademark: SWR
Origin: China
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other, Group Corporation

Basic Info.

Model NO.
TS2103
HS Code
9023009000
Production Capacity
50000 Pieces/Year

Product Description

Micro Current Sensor
Product No.: TS2103
Measuring range: -10μA~+10μA
Resolution: 0.01μA
Accuracy: ±1%F.S
Internal resistance: 300Ω
 

Introduction:
Micro Current Sensor is used to measure tiny current signal in circuit. Sensitive sampling resistor with 300Ω is designed in the sensor. When current passes through resistor, it will form a tiny electric potential difference at both ends of the resistor. After circuit amplifying, voltage is direct proportional to current. It can accurately measure the micro current.

Calibration:
TS2103 Micro Current Sensor needs to be calibrated before using. Connect sensor to datalogger. Open SWR iLab. Short connect red and black alligator clips to calibrate.

Usage:
During using, series connect Micro Current Sensor in circuit. Make sure the current flowing through it from the red wire and flowing out from black wire. The measured current value is positive under this condition as shown below:

Micro Current Sensor
Typical experiment:
Measure the electrodynamic potential and internal resistance of battery
VA characteristics of small bulb, diode and conductor
Ohm's law
Series and parallel connection of resistor
Electromagnetic induction phenomenon
LC Oscillation
Series-parallel connection, charging and discharging of capacitor
Experimental case:
VA characteristics of small bulb:
Micro Current Sensor
Product General Assembly
Experimental procedures:
  1. Connect apparatus as shown above. Calibrate micro voltage and current sensor.
  2. Open the SWR iLab V8.0. Click 'new' to create new experimental template. Click 'new page' to add new folder.
  3. Click 'add line' to add 'Micro voltage-Time' and 'Micro current-Time' curve. Set proper experiment time and acquisition interval.
  4. Click 'start' and move bar magnet to change the flux passes through circuit.
  5. Click 'stop' when collecting is completed. Observe induced voltage, current change with respect to time.
  6. Observe and analyze the experimental result.
  7. Clear up the apparatus
Micro Current Sensor
VA Curve
Notes:
1. Micro Current Sensor should be series connected to the circuit during using. Micro  Current Sensor needs to be calibrated before using.
2. When measuring, please do not make the measured current exceeding the range of the sensor.
3. If possible, ground the negative pole (black alligator clip) to ensure high accuracy.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other, Group Corporation
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Export Year